Provider: Hector L. Torres, MS, MHS — USA Triathlon Level III Coach; U.S. Business Development Manager, Winback USA
Device: Winback BACK4
Key Words: TECAR; RET; Hi-TENS; Kinvent; hip extension; strength asymmetry; low back pain; running; CrossFit; active loading
Summary
This case report describes the immediate response to one Winback session in a marathon-training runner and CrossFit athlete with low back pain. Kinvent K-Pull testing before treatment showed a 19.3% left/right asymmetry in hip extension strength. A 15-minute session of RET at 40% with Hi-TENS, combined with resisted single-leg kickbacks, was followed by retesting on the same device. Left hip extension force rose 16% and the asymmetry fell to 3.1%, an 84% reduction.
Key take-away lessons:
- One session of TECAR with concurrent active loading closed most of a 19% hip extension imbalance, as measured on Kinvent.
- The weaker side gained force rather than the stronger side simply weakening, which points to reduced pain-related inhibition.
- Pairing a hands-free TECAR setup with targeted exercise lets the clinician load the inhibited muscle while the energy is delivered.
- Pre/post dynamometry gives patients and clinicians an objective number to track across visits.
Patient Information / Diagnosis
Demographics: Adult female; marathon-training runner and CrossFit athlete.
Chief Complaint: Low back pain radiating down the lower back, disturbing sleep.
Working Diagnosis: Low back pain with hip extensor strength asymmetry and suspected compensatory lumbar loading.
Clinical Findings
Hip extension strength was tested bilaterally with a Kinvent K-Pull dynamometer, 3 repetitions per side. The right side averaged 18.27 kg peak force and the left 14.67 kg, an average asymmetry of 19.3%. A one-sided deficit of this size is a common driver of compensatory lumbar loading in runners and lifters.
Treatment and Intervention
| Parameter | Detail |
| Mode | Rehab+ |
| Modality | RET (resistive TECAR) at 40% intensity with Hi-TENS at 25 kHz |
| Electrodes | Adhesive pads over the right hip extensor/gluteal complex |
| Active loading | After the first 5 minutes, resisted single-leg kickbacks performed while RET and Hi-TENS continued |
| Total time | About 15 minutes, single session |
Adverse events: None reported.
Results
The Kinvent hip extension test was repeated immediately after treatment.
| Kinvent hip extension | Pre | Post | Change |
| Left, average peak force | 14.67 kg | 17.05 kg | +2.38 kg (+16%) |
| Right, average peak force | 18.27 kg | 16.73 kg | −1.55 kg (−8%) |
| Left/right asymmetry (3 reps) | 19.3% | 3.1% | −16.2 pts (−84%) |
Discussion
The main finding is an 84% reduction in hip extension asymmetry within one session, driven by a 16% gain on the weaker left side. A plausible mechanism is reduced pain-related inhibition: RET and Hi-TENS may lower nociceptive input and improve local tissue tolerance, allowing better motor recruitment during the concurrent kickbacks. The small drop on the right side is consistent with test-to-test variation or mild fatigue rather than a loss of strength. Limitations include the single-session design, no control condition, no pain or sleep measure recorded, and possible learning effects on repeat testing. Asymmetry, pain and sleep should be tracked across follow-up visits to confirm the change holds.